Real Fyre G18-2-16/18-12P Manuel du propriétaire

Naviguer en ligne ou télécharger Manuel du propriétaire pour Foyers Real Fyre G18-2-16/18-12P. Real Fyre G18-2-16/18-12P Owner`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 30
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
REV 7 - 1006291043
L-F2-099
OWNER’S
MANUAL
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
Burner Systems:
G18-2-16/18-12(M)(P)
G18-2-16/18-15(M)(P)
G18-2-24-12(M)(P)
G18-2-24-15(M)(P)
Log Sets:
EFV-2-(16/18, 24) Evening Fyre
ESV-2-(16/18, 24) Evening Fyre Split
ECV-2-(16/18, 24) Evening Fyre Charred
Important: Read these instructions carefully
and completely before starting
installation of the log set.
This is an unvented gas-fi red heater. It uses
air (oxygen) from the room in which it is
installed. Provisions for adequate combustion
and ventilation air must be provided. Refer to
section entitled VENTILATION AND CONFINED
SPACE INFORMATION.
This appliance is designed as an attended
appliance. Adults must be present when the unit
is operating. Do not leave this unit burning when
unattended or while anyone is sleeping.
Installation, service, and the provisions for combustion
and ventilation air MUST conform with local codes
and with the
National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or the CSA B149.1, Natural Gas And
Propane Installation Code.
This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gasses.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open a window.
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in the building.
Immediately call the gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach the gas supplier, call the
re department.
WARNING
If the information in this manual is not
followed exactly, a fire or explosion
may result, causing property damage,
personal injury, or loss of life.
This appliance is only for use
with the type of gas indicated
on the rating plate.
Installation and service must be performed
by a qualifi ed professional installer, service
agency, or the gas supplier.
DESIGN CERTIFIED
to
Unvented Room Heater Standard
ANSI Z21.11.2-2007
and
Vented Decorative Appliance
ANSI Z21.60b-2004
254-L-12e-5
G18-2 SERIES UNVENTED GAS LOG SETS
24" Model shown
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - OWNER’S

1REV 7 - 1006291043L-F2-099OWNER’S MANUALROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746Burner Systems:G18-2-16/18

Page 2 - CONTENTS

10MINIMUM CLEARANCE TO COMBUSTIBLES 14"12"34"32"HorizontalProjectionFrom face ofFireplaceNon-combustibleOr heat resistantMaterialT

Page 3 - Fireplace Dimensions

11LOGS - PARTS LISTWARNINGFailure to position these parts in accordance with these diagrams or failure to use only parts specifi cally approved with th

Page 4

12 EFV-2-24 24" EVENING FYRE LOG SETITEM PART DESCRIPTION NO. NO. 1. EFVL-2-24BF Bottom front log (2) 2. EFVL-2-12T Top Y-shape

Page 5 - IMPORTANT SAFETY INFORMATION

13BURNER PARTS LIST ITEM DESCRIPTION NO. 1. Grate assembly 2. Valve assembly (propane) or Valve assembly (natural) 3. Ember burner 4. ODS pi

Page 6

14BURNER PARTS LIST (Cont.) ITEM DESCRIPTION NO. 1. Grate assembly 2. Valve assembly (propane) or Valve assembly (natural) 3. Ember burner 4.

Page 7

15BURNER PARTS LIST (Cont.)G18-2-24-12(M)(P) ITEM DESCRIPTION NO. 1. Grate assembly 2. Valve assembly (natural) or Valve assembly (propane) 3.

Page 8

16BURNER PARTS LIST (Cont.)G18-2-24-15(M)(P) ITEM DESCRIPTION NO. 1. Grate assembly 2. Valve assembly (natural) or Valve assembly (propane) 3.

Page 9 - Fig. 9-1

17This appliance is for installation in a solid-fuel burning fi replace (masonry fi replace or manufactured fi replace) with a working fl ue and construct

Page 10 - Mantel clearance without hood

18IMPORTANTWARNINGDo not connect this appliance directly to a high-pressure natural gas line or an unregulated propane tank.INSTALLATIONThe gas log se

Page 11 - LOGS - PARTS LIST

19GLOWING EMBER PLACEMENTThe Glowing Embers are supplied in a single bag (Fig. 19-2). It is important that the embers be used in the designated applic

Page 12 - LOGS - PARTS LIST (Cont.)

2REV 7 - 1006291043L-F2-099CONTENTSImportant: For safe operation and proper performance of this product and to comply with certifi cation, listings, an

Page 13 - G18-2-16/18-12(M)(P)

20INSTALLATION (Cont.)1. Use the space between the grate and main burner as a guide to set the two (2) bottom logs (Logs #1) in their approximate pos

Page 14 - G18-2-16/18-15(M)(P)

21After setting the logs into position as described on the previous page, ensure each is properly and fi rmly seated. The vent-free gas log set will no

Page 15 - G18-2-24-12(M)(P)

22CLEANING AND SERVICING SAFETY INFORMATIONFig. 22-1ODS pilot (opposite side)Main burner portsEmber burner ports (each side)Gas valveCarryover port lo

Page 16 - G18-2-24-15(M)(P)

23Only limited cleaning will be required under normal use of the unvented gas log set.TO CLEAN THE LOG SET 1. Remove the log set and embers. Use a va

Page 17 - IMPORTANT

24Observe the fl ames. The main burner fl ames should be blue at the base and a combination of blue/yellow at the body and at the tips. They should be 5

Page 18 - INSTALLATION

WARNINGIf you do not follow these instructions exactly, a fi re or explosion may result, causing property damage, personal injury, or loss of life.LIGH

Page 19 - INSTALLATION (Cont.)

261. Locate your Series 12 control valve (p. 15). Turn the control knob (Fig. 26-4) from the OFF position (see Fig. 26-1) slightly counterclockwise

Page 20

27TROUBLESHOOTINGPOSSIBLE CAUSE SOLUTIONSBURNER SHUTTING DOWN DURING OPERATIONA. Insufficient or excessive gas pressureA1. Check gas pressure (check

Page 21

28TROUBLESHOOTING (Cont.)HIGH CO - CARBON MONOXIDE DETECTORS IN HOME TURNING ALARM ONA. High CO levels A. TURN OFF UNIT IMMEDIATELY.B. Call a quali

Page 22 - " (minimum)

29TROUBLESHOOTING (Cont.)POSSIBLE CAUSE SOLUTIONSA. Low gas pressure A. Check gas pressure.B. Drafts in room B. Eliminate drafts by closing heatin

Page 23 - CLEANING AND SERVICING

3REV 7 - 1006291043L-F2-099G18 SPECIFICATIONS AND REQUIREMENTSThe minimum size of fi replace for installation of the Real-Fyre® G18-2 heater gas log se

Page 24 - ODS Pilot for 12 valve

30PLEASE KEEP A COPY OF YOUR SALES SLIP FOR PROOF OF PURCHASEThis warranty applies to the original purchaser and to single family residential use only

Page 25 - Gas valve operating positions

4WARNINGTHIS APPLIANCE IS EQUIPPED FOR (NATURAL OR PROPANE) GAS.FIELD CONVERSION IS NOT PERMITTED.PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETYA.

Page 26 - PILOT POSITION

5ANSI Z21.11.2-2007 UNVENTED ROOM HEATER GENERAL SAFETY INFORMATIONA. WARNING: CARBON MONOXIDE POISONING MAY LEAD TO DEATH. When used without fresh

Page 27 - TROUBLESHOOTING

6INSTALLATION SAFETY INFORMATIONINSTALLATION SAFETY GUIDELINESA. Carefully inspect the burner and log cartons for shipping damage. If any parts are m

Page 28 - POSSIBLE CAUSE SOLUTIONS

7OPERATIONAL SAFETY INFORMATIONOPERATING YOUR UNVENTED GAS APPLIANCE SAFELY AND CORRECTLYA. SOLID FUEL MUST NOT BE BURNED in a fi replace where this v

Page 29

8OPERATIONAL SAFETY INFORMATION (Cont.)OPERATING YOUR UNVENTED GAS APPLIANCE SAFELY AND CORRECTLYM. This appliance is intended for supplemental heati

Page 30 - COMMONWEALTH OF MASSACHUSETTS

9Installation in a tightly constructed home and/or installation at high altitudes may cause your vent-free gas log set to produce excessive heat or ex