1REV 5 - 0707021037L-F2-08307OWNER’S MANUALDESIGN CERTIFIEDtoVent-free Room Heater StandardANSI Z21.11.2-2007and Vented Decorative ApplianceANSI Z21.6
10MINIMUM CLEARANCE TO COMBUSTIBLES HOW TO CORRECTLY SIZE AND INSTALL MANTELS AND FIREPLACE HOODSA. ABOVE THE FIREPLACE:To install the unvented gas lo
11This appliance is for installation in a solid-fuel burning fi replace (masonry fi replace or manufactured fi replace) with a working fl ue and construct
12LOGS - PARTS LISTWARNINGFailure to position the parts in accordance with these diagrams, or failure to use only parts specifi cally approved with thi
13BURNER PARTS LIST FOR MILLIVOLT VALVEITEM NO.DESCRIPTION1.Piezo ignitor (1)2.Switch (2)3.Front burner (1)4.Valve (natural) (1)Valve (propane) (1)5.C
141. Center the burner assembly in the fi replace. Make certain that no part of the assembly protrudes beyond the face of the fi replace.2. Attach th
15IMPORTANTMillivolt Safety Pilot Valve (Fig. 15-1)The valve regulator controls the burner pressure which should be checked at the pressure inlet poin
16GLOWING EMBER AND LOG PLACEMENTGLOWING EMBER PLACEMENTYour glowing embers are provided in a bag labelled glowing embers. It is very important that y
17Fig. 17-3Fig. 17-43. Position the two (2) smaller “Y” top logs (Log #3) on the top of the intermedi-ate and bottom logs, as shown in Fig. 17-3. Loc
18OPERATING YOUR LOG SET - LIGHTING AND EXTINGUISHINGA. BEFORE LIGHTING, smell all around the gas log set area for gas. Be sure to smell next to the fl
19OPERATING YOUR REAL-FYRE®® HEATER GAS LOG SETYour Real-Fyre® heater gas log set is now ready for you to enjoy. Follow LIGHTING INSTRUCTIONS. Then,
2REV 5 - 0707021037L-F2-08307CONTENTSCONTENTS 2GENERAL INFORMATION 3FIREPLACE SIZE REQUIREMENTS AND BTU RATING INFORMATION 3PRE-INSTALLATION A
20CLEANING AND SERVICINGAIR INTAKEOPENINGSTO VALVEBLOW AIR INTO THIS ENDOF TUBING ATTACHED TOVALVE (INPUT SIDE)Fig. 20-1Fig. 20-2A. Always shut off t
21CLEANING AND SERVICINGAIR INTAKEOPENINGSPILOT OPENINGCOMPRESSEDAIR DUSTERFLEXIBLENOZZLEFig. 21-2Fig. 21-1DISCONNECT PILOT GAS LINEAND BLOW AIR THROU
ADJUSTING THE ODS PILOTa. The ODS pilot fl ame should encircle the generator tip, and is preset at the factory (Fig. 22-2). Ordinarily, the ODS pilot
23TROUBLESHOOTINGPOSSIBLE CAUSE SOLUTIONSBURNER SHUTTING DOWN DURING OPERATIONA. Insufficient or excessive gas pressureA1. Check gas pressure (check
24TROUBLESHOOTING (Cont.)HIGH CO - CARBON MONOXIDE DETECTORS IN HOME TURNING ALARM ONA. High CO levels A. TURN OFF UNIT IMMEDIATELY.B. Call a qualifi
25TROUBLESHOOTING (Cont.)POSSIBLE CAUSE SOLUTIONSA. Low gas pressure A. Check gas pressure.B. Drafts in room B. Eliminate drafts by closing heatin
26PETERSON VENT-FREE GAS LOG SETS LIMITED WARRANTYAll Peterson vent-free ceramic refractory gas logs are WARRANTED for as long as you own them (lifeti
3REV 5 - 0707021037L-F2-08307GENERAL INFORMATIONFIREPLACE SIZE REQUIREMENTS AND BTU RATING INFORMATIONThe minimum size of fi replace for installat
4PRE-INSTALLATION AND FIREPLACE PREPARATION SAFETYA. This appliance is designed as an attended appliance. Adults must be present when this gas applia
5CAUTION: Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional installer. Installer: Carefully read these instru
6INSTALLATION SAFETY INFORMATIONINSTALLATION SAFETY GUIDELINESA. Before installing in a solid-fuel-burning fi replace, the chimney fl ue and fi rebox mu
7OPERATIONAL SAFETY INFORMATIONCAUTION: Installation and repair must be done by an NFI Certifi ed or other qualifi ed professional installer. Installer
8OPERATIONAL SAFETY INFORMATION (Cont.)OPERATING YOUR UNVENTED GAS LOG SET SAFELY AND CORRECTLYO. Vent-free gas logs are supplemental zone heaters, n
9Installation in a tightly constructed home and/or installation at high altitudes may cause your vent-free gas log set to produce excessive heat or ex